RESEARCH CONCEPTS RC3000 Especificações Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 17
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
Note that the cable service loop at the back of the controller should be long enough to allow the unit to be pulled out of its
mounting rack with the cabling attached to perform internal adjustments. Also note that the controller’s J1, J3, J6, J7, and
J10 connectors are identical to those on the back of the RC8097 controller. A back panel diagram is included in the
appendix of this document.
The following table describes the connectors on the back of the RC3000.
Designation Type Function
J1 DB15 female az/el/pol position sense
J2 DB15 female AGC port (RC3000TRK)
J3 DB15 female limit switches
J4 DB15 male Pulse sensor input (RC3000TRK)
J5 DB9 female Serial Comm. Port (RC3000CRC
J6 IEC fused Power Entry
J7 Amphenol 22-20S az/el/pol motors
J8 Amphenol 126-221 HPA disable and accessories
J9-GPS DB9 female on dongle GPS & cable, (RC3000GPS)
J9-FG DB9 female on dongle FG Compass & cable (RC3000FG)
J10 DB25 female Handheld Remote Control (RC3000HRC)
J11 F female Block LNB signal for auto peak
The following table lists the types of cable employed in the cabling kits produced by RCI.
Cable Type Cable Configuration Controller Wiring Harness Circuit
Alpha 2432C 2 x 16 AWG shielded with bare drain wire Az/El/Pol Motors
Belden 9770 3 x 22 AWG shielded with bare drain wire Az/Pol Potentiometer and Single Phase pulse
position encoders.
Alpha 2404C 4 x 22 AWG shielded with bare drain wire Elevation Inclinometer and Limit Switches
(containing two limit switch circuits, i.e.
elevation up and elevation down)
Alpha 1292C 2 x 22 AWG shielded with bare drain wire Limit Switches
Power Entry
Connector J6 accepts an IEC type AC power plug. RC3000 controllers can be configured at the factory for either 115 or 230
VAC operation. The AC line cord supplied with the controller is appropriate for the controller’s AC power configuration. The
controller’s AC line voltage configuration can be determined by viewing the window on the power entry module. The window
will either display ‘115’ or ‘230’.
The RC3000A can be configured by the user in the field for operation at either 115 or 230 VAC line voltage.
Use the following procedure to re-configure the RC3000A’s AC power configuration …
1. Switch off the controller.
2. Remove the IEC power cord from the back panel entry module.
3. With a small, straight bladed screw driver remove the fuse drawer and the fuse from the power entry module.
Vista de página 1